Saturday, June 16, 2012

OBIEE 11g Error: 500 Internal Server Error

Hi,


I have installed obiee11.1.1.6.0 with weblogic server 10.3.5.0 and when ever i try to start the BI services. I am getting the error following error 

Error 500--Internal Server Error 
From RFC 2068 Hypertext Transfer Protocol -- HTTP/1.1:
10.5.1 500 Internal Server Error
The server encountered an unexpected condition which prevented it from fulfilling the request.


I thought still some of bi services are trying to starting like that so that's why its taking time and all after searching oracle note i just found actual reason is 

FMW_SECURITY_SERVICES_URL in NQSConfig.ini has wrong IP. checking log file its noticed that this parameter has invalid IP which caused the problem.so after updating with correct IP address its got working fine so this is permanent solution.

FYI, the screen short just find the FMW_SECURITY_SERVICES_URL in NQSConfig.ini file.







 Try to update your static IP address like below screen,



Then try to re - start your bi services then Error: 500 Internal Server Error won't come again.





Regards,
Deva...

4 comments:

  1. Is there any way that I can customize this error message?
    error 500--internal server error

    ReplyDelete
    Replies
    1. yes...you need to add customised xml pages with customised error and add one tag in META.INF page in analytics.ear application and redeploy it.

      Delete
  2. The IP is correct in the NQSCOnfig.ini file. Yet i Get the same message. Can anyone help??

    ReplyDelete
  3. Check in the services.msg if and node manager services Oracle WebLogic NodeManager is running . Disable that. then stop the bi services and start again. No need to change the ip in NQSCOnfig.ini file.

    ReplyDelete